AXIS M5013 PTZ Dome Network Camera
Detectors
Parameter
Object Size
History
Sensitivity
Description
Object size r ela tive to window
size.
Object memory length.
Difference in luminance
between background and
object.
High level (100%)
Only very large objects trigger
motion detection.
An object that appears in
the window triggers motion
detection for a long time
before it is co nsidered as
non-moving.
Ordinary colored objects on
ordinary backgrounds trigger
motion detection.
Medium level (50%)
A large difference in luminance
is required to trigge r motion
detection.
Low level (0%)
Even very small objects trigger
motion detection.
An object that appears in
the window triggers motion
detection only for a very short
time before it is considered as
non-moving.
Only very bright objects on
a dark background trigger
motion detection.
Recommended values
5–15% 60–90% 75–95%
Default values
15% 90% 90%
Tips:
To trigger on small objects or m ovements, use several small motion detection windows rather than one large w indow
and select a low object size.
To avoid triggering on small objects, select a high object size.
If no objects should appear in the Include Window, select a high history level. This will cause motion detection to trigger as
long as the object is present in the window.
To only detect ashing light, select a low sensitivity. In other cases high sensitivity is recommended.
Audio d etection
The Axis p roduct can be congured to generate an alarm when audio rises above or falls below the threshold value. The threshold
value can be set in the range 0–100 where 0 is the most sensitive and 100 the least sensitive.
1. Go to Detectors > Audio Detection.
2. Set the audio alarm level and click Save.
3. Go to Events > Action Rules and set up an action rule, see Setting Up an Action Rule, on page 27.
Note
Au
dio alarm is disabled by default during PTZ movement. To enable, clear the Alarm automatically disabled during PTZ
movement check box option.
Detected audio is indicated by colored peaks in the Activity indicator. An e v ent is triggered when detected audio rises above or falls
below the threshold value, w hich is represented by the bar.