AXIS M5013 PTZ Dome Network Camera
Events
Events
The Axis p roduct can be configured to perform actions when different events occur, for example, start a rec ording w h en motion is
detected. The set of conditions that defines how and when the action is triggered is called an Action Rule.
Available Action Rul e triggers and conditions include:
• Applications — use installed applications to trigger the r u le, see Applications, on page 25.
• Detectors
- Audio Detection — trigger the rule when audio is detected, see Audio detection, on page 24.
- Motion Detection — trigger the rule when motion is detected, see Motion Detection, on page 23.
• Hardware
- Network — trigger the rule if network connection is lost o r resto red. This can for example be used to s tart
recording to the SD card.
- Temperature — trigger the rule if the temperature falls outside or inside the operating range of the product. This
canforexamplebeusedtosendmaintenancenotifications.
• Input Signal
- Manual Trigger — trigger the rule using the Manual Trigger button in the Live View page, see Controls on
the Live View page, on page 9 . This can for example be used to validate actions during product installation
and c onfiguration.
• PTZ
- Moving — trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video w hile the
camera view moves due to a PTZ operation.
- Preset Reached — trigger the rule when the camera stops a
t a preset position. This can be for example be used
with the Send Images action to upload images from the preset positio n.
• Storage
- Available — trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance notifications.
- Full — trigger the rule when the storage device is full. Under normal op eration, the oldest recordings will be
overwritten to pre
vent the storage device from becoming full.
- Locked —tr
igger the rule if the stor age device is locked (write protected).
• Syste
m
- S
ystem Initializing — trigger the rule when the product is being started. This can for example be used to send a
notification when the pro duct restarts.
• Time
-
Recurrence — trigger the rule periodically, see Recurrences, on page 28. This can for example be used to upload
an image every 5 minutes.
- Use Schedule — trigger the rule according to the selecte d schedule, see Schedules, on page 28.
Available actions include:
• PTZ Control
26